Important – Yaskawa FSP Amplifier User Manual

Page 199

Advertising
background image

FSP Amplifier User’s Manual

Chapter 7: Using the Panel Operator

7-8

„

Function Selection Parameters

Function Selection Parameter Types

The following table shows the parameters for selecting servo amplifier
functions.

Category

Parameter

Number

Name

Default
Setting

Important

Note

Pn000

Function Selection Basic Switches

0000

(See 1)

Pn001

Function Selection Application
Switches 1

0000 (See

1)

Pn002

Function Selection Application
Switches 2

0000 (See

1)

Function Selection
Parameters

Pn003

Function Selection Application
Switches 3

0002 —

Gain-related Parameters

Pn110

Online Auto-tuning Switches

0010

(See 2)

Position Control
related Parameter

Pn200

Position Control Reference
Selection Switches

0000 (See

1)

Pn50A

Input Signal Selections 1

2100

(See 1)

Pn50B

Input Signal Selections 2

6543

(See 1)

Pn50C

Input Signal Selections 3

8888

(See 1)

Pn50D

Input Signal Selections 4

8888

(See 1)

Pn50E

Output Signal Selections 1

3211

(See 1)

Pn50F

Output Signal Selections 2

0000

(See 1)

Sequence-related
Parameters

Pn510

Output Signal Selections 3

0000

(See 1)

IMPORTANT

1. After changing these parameters, turn OFF the main circuit and control power supplies and then
turn them ON again to enable the new settings.
2. Changing bits Pn10B.1 and Pn110.0 require the same sequence described in note 1 (above).

Advertising