FSP Amplifier User’s Manual

Chapter 9: Inspection, Maintenance, and Troubleshooting

9-23

„

A.84: Absolute Encoder Data Error

Display and Outputs

Alarm Outputs

Alarm Code Output

ALO1 ALO2

ALO3

ALM Output

OFF OFF

OFF

OFF

Note: OFF: Output transistor is OFF (alarm state).

Status and Remedy for Alarm

At power ON.

During servomotor

operation

A

B

Cause of the Problem

Solution

A

Malfunctioning absolute encoder.

Replace servomotor if error occurs
frequently.

B

Operational error in encoder
caused by external noise

Check and correct wiring around the
encoder, (grounding of servomotor,
separation of encoder and power
cables, insertion of toroidal cores onto
cables to reduce noise, etc.)