Appendix B: Special Wiring

B-4

„

MCCB or Fuse According to Power Capacity

The following table shows the MCCB or fuse capacity for each power
supply capacity.

Servo Amplifier

Model

Main Circuit
Power
Supply

Capacity

(kW)

FSP-

Applicable

Motor

Power

Capacity per

Servo

Amplifier

(kVA)

*1

Current

Capacity per

MCCB or

Fuse(A

rms

)

*1,2

0.03 A3B*

SGMAH-A3B 0.15

0.05 A5B*

SGMAH-A5B 0.25
SGMAH-01B

0.10 01B*

SGMPH-01B

0.40

4

SGMAH-02B

Single-phase
100 V

0.20 02B*

SGMPH-02B

0.60 6

0.03 A3A*

SGMAH-A3A 0.20

0.05 A5A*

SGMAH-A5A 0.25
SGMAH-01A

0.10 01A*

SGMPH-01A

0.40

SGMAH-02A

0.20 02A*

SGMPH-02A

0.75

4

SGMAH-04A

Single-phase
200 V

0.40 04A*

SGMPH-04A

1.2 8

SGMAH-08A

0.75 08A*

SGMPH-08A

2.1 11

Single-phase
220 V

1.50 15A*

SGMPH-15A

4.0

19

SGMGH-09A

1.00 10A*

SGMSH-10A

2.3 7

SGMGH-20A

2.00 20A*

SGMSH-20A

4.3 13

SGMGH-30A

Three-phase
200 V

3.00 30A*

SGMSH-30A

5.9 17

0.50 05D*

SGMGH-05D

1.1

1.6

SGMGH-09D
SGMSH-10D

1.00 10D*

SGMUH-10D

2.3 3.4

SGMGH-13D
SGMSH-15D

1.50 15D*

SGMUH-15D

3.2 4.6

SGMGH-20D

2.00 20D*

SGMSH-20D

4.9 7.1

SGMGH-30D
SGMSH-30D

3.00 30D*

SGMUH-30D

6.7 9.7

SGMGH-44D
SGMSH-40D

Three-phase
400 V

5.00 50D*

SGMSH-50D

10.3 14.9

*1. This is the net value at the rated load. When actually selecting fuses, determine the capacity using the prescribed

derating.

*2. Operating characteristics (at 25°C): 2 seconds or more for 200%, 0.01 second or more for 700%

Note: 1. A fast-operating fuse cannot be used because the servo amplifier power supply is a capacitor input type. A

fast-operating fuse may blow when the power is turned ON.

2. FSP Amplifiers do not have built-in ground protection circuits. To configure a safer

system, install a ground fault interrupter with or without a circuit breaker for protection against