Pso serial data specifications – Yaskawa FSP Amplifier User Manual

Page 153

Advertising
background image

FSP Amplifier User’s Manual

Chapter 5: Parameter Settings and Functions

5-86

„

Detailed Signal Specifications

PAO Serial Data Specifications

The number of revolutions is output in five digits.

Data Transfer

Method

Start-stop Synchronization

(ASYNC)

Baud rate

9600bps

Start bits

1 bit

Stop bits

1 bit

Parity Even
Character code

ASCII 7-bit code

Data format

8 characters, as shown below

Note:


1.

Data is “P+00000” (CR) or “P-00000” (CR) when the number of revolutions is zero.

2.

The revolution range is “+32767” to “-32768.” When this range is exceeded, the data changes from

“+32767” to “-32768” or from “-32768” to “+32767”

PSO Serial Data Specifications

The number of revolutions and the absolute position within one revolution
are always output in five and seven digits, respectively. The data output
cycle is approximately 40ms.

Data Transfer

Method

Start-stop Synchronization

(ASYNC)

Baud rate

9600bps

Start bits

1 bit

Stop bits

1 bit

Parity Even
Character code

ASCII 7-bit code

Data format

13 characters, as shown below

Note:


1.

The absolute position data within one revolution is the value before dividing.

2.

Absolute position data increases during forward rotation. (Not valid in reverse rotation mode).