Using /p-cl and /n-cl signals – Yaskawa FSP Amplifier User Manual

Page 78

Advertising
background image

FSP Amplifier User’s Manual

Chapter 5: Parameter Settings and Functions

5-11

The following output signals and monitor methods are used when torque is
being limited.

Signal Description

/CLT

Generated when Pn50F.0 is allocated to an
output terminal from SO1 to SO3.

Monitor Mode (Un006)

Un005: Numbers 6 and 7 (with default
settings)

Refer to 7.1.6 Operation in Monitor Mode.

Un006: Depending on output signal
allocation conditions.


Application Examples:
• Forced stop

• Robot holding a workpiece

Parameter Signal

Setting

(% of Rated Torque)

Control Mode

Pn404

Forward External Torque Limit

Range: 0 to 800
Default Setting: 100

Speed, Torque, and
Position Control

Pn405

Reverse External Torque Limit

Range: 0 to 800
Default Setting: 100

Speed, Torque, and
Position Control

Set the torque limits when the torque is limited by an external contact
input.

Signal Description

/P-CL (CN1-45) Input

Pn404 torque limit applied.

/N-CL (CN1-46) Input

Pn405 torque limit applied.

See 5.2.9 Torque Limiting by Analog Voltage Reference.

Using /P-CL and /N-CL Signals

The procedure for using /P-CL and /N-CL as torque limit input signals is
illustrated below.