Selection of control mode – Yaskawa FSP Amplifier User Manual

Page 169

Advertising
background image

FSP Amplifier User’s Manual

Chapter 6: Servo Adjustment

6-2

6.1. Selection of Control Mode

The FSP servo amplifier offers speed control, position control, torque control,
and the other control modes shown in the following table.
The following parameter is used to set the control mode.

Parameter Signal

Setting

Control

Mode

Pn000.1

Control Method
Selection

Default Setting: D

Speed, Torque,
Position Control,
and Programming

Pn000.1 Setting

Control Mode

0

Speed Control (Analog Reference)

2

Torque Control (Analog Reference)

3

Contact Input Speed Control Selection (Contact Reference)

4

Contact Input Speed Control Selection (Contact Reference)

↔ Speed Control

(Analog Reference)

6

Contact Input Speed Control Selection (Contact Reference)

↔ Torque Control

(Analog Reference)

8

Position Control (Pulse Train Reference)

↔ Torque Control (Analog Reference)

9

Torque Control (Analog Reference)

↔ Speed Control (Analog Reference)

A

Speed Control (Analog Reference)

↔ Zero Clamp Control

B

Position Control (Pulse Train Reference)

↔ Position Control (Inhibit)

C

Position Control (Pulse Train Reference)

D

NCT Position Control, NCT Speed Control, Torque Control (Serial Communication
Command), Programming

Whenever Speed Control or Position Control is selected, the Loop Gain
parameters should be adjusted in order to ensure a stable and smooth operation.
Adjustment of Speed Control using Analog Input or Contact Input is described
below in section 6.2, for setting cases of Pn000.1 = 0, 3, 4, 6, 9 and A.
Adjustment for Position Control or NCT Velocity Control is described below in
section 6.3, for setting cases of Pn000.1 = 8, B, C and D.

Advertising