A.c1: servo run away, Display and outputs, Status and remedy for alarm – Yaskawa FSP Amplifier User Manual
Page 292

FSP Amplifier User’s Manual
Chapter 9: Inspection, Maintenance, and Troubleshooting
9-27
A.C1: Servo Run Away
Display and Outputs
Alarm Outputs
Alarm Code Output
ALO1 ALO2 ALO3
ALM Output
ON OFF
ON
OFF
Note: OFF: Output transistor is OFF (alarm state).
ON: Output transistor is ON.
Status and Remedy for Alarm
At power ON.
When parameter
Pn 50A.1 = 7.
When Servo ON
(S-ON) signal is
turned ON.
A
A, B, C, D
D
When the speed
reference is
entered.
Within 1 to 3
seconds after power
is turned ON.
When parameter
Pn 50A.1 7.
A
A, B, C, D
A, B, C
≠
Cause of the Problem
Solution
A
Incorrect or disconnected
servomotor wiring.
Check wiring and connectors
at the servomotor.
B
Incorrect or disconnected
encoder wiring.
Check wiring and connectors
at the encoder.
C
Defective encoder.
Replace servomotor.
D
Defective circuit board (1PWB).
Replace servo amplifier.