FSP Amplifier User’s Manual

Chapter 5: Parameter Settings and Functions

5-58

V-REF speed reference

Speed

Preset value for zero clamping

/P-CON (/ZCLAMP) input

Open (OFF)

Closed
(ON)

Time

Zero clamp is performed

Note:

When the /ZCLAMP signal is allocated, the zero clamp operation will be used even for speed control
(Pn000.1 = 0).

5.4.4. Using the Holding Brake

The holding brake is used when a FSP Amplifier controls a vertical axis. In
other words, a servomotor with brake prevents the movable part from
shifting due to the force of gravity when system power goes OFF.

Servom otor

Holding brake

Prevents the
Servomotor from
rotating due to gravity
when system power
goes OFF.

„

Wiring Example

Use the servo amplifier contact output signal /BK and the brake power
supply to form a brake ON/OFF circuit. The following diagram shows a
standard wiring example.

FSP Amplifier