FSP Amplifier User’s Manual

Appendix B: Special Wiring

B-15

B.6. Reactor for Harmonic Suppression

FSP Amplifiers have DC reactor connection terminals for power supply
harmonic suppression.

„

Connecting a DC Reactor

The DC reactor is connected in series to the rectifier circuit’s output side.
Refer to 3.2 FSP Amplifier Internal Block Diagrams.

+ 1

+ 2

DC reactor

FSP Amplifier

By default the FSP Amplifier is shipped with (+)1 and (+)2 terminal short-
circuited. Remove the lead wire between the two terminals and connect the
DC reactor instead.

„

DC Reactor Specifications

For DC reactor specifications provided by Yaskawa, refer to Appendix C
of this manual.