Analog input or contact input velocity control, 1+ 1/t – Yaskawa FSP Amplifier User Manual

Page 170

Advertising
background image

FSP Amplifier User’s Manual

Chapter 6: Servo Adjustment

6-3

6.2. Analog Input or Contact Input Velocity Control

This section provides technical information for operation of servomotors in
Velocity Control mode with Analog Input.
The Identical Control principle is applied in case of Contact Input or Analog
Input. In case of Contact Input, the velocity command value is retrieved from one
of the predefined values, according to the Contact Input setting.
Instructions and descriptions referring to Analog Input in the following sections
also apply to Contact Input.

6.2.1. Principle and Block Diagram of the Velocity Control






















Command

Smoothing

Analog Input

Speed Command

+

+

Offset Compensation

Input Gain

K

v

(1+ 1/T

i

S)

Notch Filter

Low Pass
Filter

Internal Speed
Command

1/K

t

Torque
Command

Current Controller



Motor

Encoder

Current
Command

S

+

-

Speed Loop Gains

Contact Input Predefined Speed