Related parameters, Select the /bk output terminal – Yaskawa FSP Amplifier User Manual

Page 126

Advertising
background image

FSP Amplifier User’s Manual

Chapter 5: Parameter Settings and Functions

5-59

Output Ö /BK

Brake Interlock Output

Speed, Torque, Position Control, and
Programming

This output signal controls the brake when using a servomotor with a brake
and does not have to be connected when using a servomotor without a
brake.

State Status

Result

ON:

Closed or low level

Releases the brake.

OFF:

Open or high level

Applies the brake.


Related Parameters

Parameter Description

Pn506

Time Delay from Brake Reference until Servo OFF

Pn507

Speed Level for Brake Reference Output during Motor Operation

Pn508

Timing for Brake Reference Output during Motor Operation

The following parameter must be selected to determine the location of the
output signal, when the /BK signal is used.

Parameter Signal

Setting Control

Mode

Pn50F

Output Signal Selections 2 Default Setting: 0000

Speed, Torque, Position
Control, and Programming

/BK

Brake interlock

output

SO1 (CN1-25, 26)

SO2 (CN1-27, 28)

SO3 (CN1-29, 30)

Pn50F.2

1

2

3

Output terminals

Select the /BK output terminal.

Output Terminal (CN1)

Parameter Setting

*

1

*

2

0 — —
1 25 26
2 27 28

Pn50F.2

3 29 30

Note:

Signals are output with OR logic when multiple signals are allocated to the same output circuit. Set other
output signals to a value other than the one allocated to the /BK signal in order to output the /BK signal
alone. See

5.3.4 Output Circuit Signal Allocation.

Advertising