FSP Amplifier User’s Manual

Chapter 7: Using the Panel Operator

7-11

7. Press the DATA/SHIFT key once more for a minimum of one second

to return to the parameter number display.

This has changed the 1 digit of parameter Pn000 to “1”.

7.1.6. Operation in Monitor Mode

The Monitor mode can be used for monitoring the reference values, I/O
signal status, and servo amplifier internal status.
The Monitor mode can be set during motor operation.

„

Using the Monitor Mode

The example below shows how to display 1500; the contents of monitor
number Un000 when the servomotor rotates at 1500 rpm.
1. Press the MODE/SET key to select the Monitor mode.

2. Press the Up Arrow or Down Arrow key to select the monitor number

to be displayed.

3. Press the DATA/SHIFT key for a minimum of one second to display

the monitor number selected in step 2 above.

4. Press the DATA/SHIFT key once more for a minimum of one second

to return to the monitor number display.

This has changed the 1 digit of parameter Pn000 to “1”.

This completes the example procedure for displaying 1500; the contents of
monitor number Un000.