FSP Amplifier User’s Manual

Chapter 5: Parameter Settings and Functions

5-84

5.7.4. Absolute Encoder Reception Sequence

This section describes the sequence in which the servo amplifier receives
data from the absolute encoder and transmits it to the host device. Be sure
you understand this section when designing the host device.

„

Outline of Absolute Signals

The absolute encoder’s outputs are PAO, PBO, PCO, and PSO signals as
shown below.

FSP Amplifier

Signal Status

Contents

Initial State

Serial data
Initial incremental pulse

PAO

Normal State

Incremental pulse

Initial State

Initial incremental pulse

PBO

Incremental pulse

PCO

Home position pulse

PSO

Normal State

Rotation count serial data

„

Contents of Absolute Data

• Serial data: Indicates how many turns the motor shaft has made from

the reference position (position specified at setup).

• Initial incremental pulse: Outputs pulses at the same pulse rate as when

the motor shaft rotates from the home position to the current position at
approximately 2500rpm (for 16 bits when the dividing pulse is at the