A.74: overload of surge current limit resistor – Yaskawa FSP Amplifier User Manual

Page 283

Advertising
background image

FSP Amplifier User’s Manual

Chapter 9: Inspection, Maintenance, and Troubleshooting

9-18

„

A.74: Overload of Surge Current Limit Resistor

Display and Outputs

Alarm Outputs

Alarm Code Output

ALO1 ALO2

ALO3

ALM Output

ON ON

ON

OFF

Note: OFF: Output transistor is OFF (alarm state).

ON: Output transistor is ON.

Status and Remedy for Alarm

When the circuit

power is turned

ON or OFF

At power ON.

A

B

Cause of the Problem

Solution

A

Frequently turning the main
circuit power ON/OFF.

Do not repeatedly turn
ON/OFF the main circuit
power.

B

Defective circuit board (1PWB).

Replace servo amplifier.