4) dc power supply input, A) main circuit and control power supply input, Warning – Yaskawa SGDS Sigma III Servo Amplifier User Manual

Page 109: 6 (4) dc power supply input

Advertising
background image

5 Wiring

5.1.3 Typical Main Circuit Wiring Examples

5-6

(4) DC Power Supply Input

When using the SGDH SERVOPACK with DC power supply input, use the following power supply and set the
parameter Pn001.2 for ‘1’. Also, read carefully to the following ‘Important’ section.

(a) Main Circuit and Control Power Supply Input

The following shows the connection for the main power supply and the control power supply.

1. Servomotor returns the regenerative energy to the power supply when regenerating. SERVOPACK does

not regenerate with DC power supply input specifications, so regenerate the energy on the power supply
side.

2. Take appropriate measures to ensure that a high charging current stays inside the SERVOPACK when

power is OFF.

• Do not use a DC power supply for 100V SERVOPACK SGDS-

F

A DC power supply will destroy the SERVOPACK, which may cause a fatal accident or fire.
Do not change the factory setting for Pn001, which is preset to ZERO (n. 000), indicating that “DC power supply
input not supported”.

• 200V SERVOPACK SGDS-

A

is applicable for both AC and DC power supply input.

However, if the DC power supply input supplies a voltage without setting ‘Pn001 = n. 1

’ (for DC power

supply input), the SERVOPACK’s internal elements will burn and may cause fire or malfunction.
When using the SERVOPACK with DC power supply input, confirm the following setting of parameters.

WARNING

Terminal Symbol

Name

Functions

B1/

Main circuit plus
terminal

270 V to 320 VDC

or 2

Main circuit minus
terminal

0 V

L1C, CL2C

Control power
supply input terminal

270 to 320 VDC, without polarity

IMPORTANT

Advertising