6.3 Main Commands

6-13

6.3.7 Clear Alarm or Warning (ALM_CLR: 06H)

* Alarm occurrence history is saved on E

2

PROM, and will not be lost if power goes OFF.

• Details of ALM_CLR_MOD

Byte

ALM_CLR

Description

Command

Response

1

06H

06H

Processing
classifications

Control com-
mand group

Synchronization
classifications

Asynchronous

2

ALARM

Processing time

Refer to
• Details of
ALM_CLR_MOD

Subcommand

Cannot be used

3

STATUS

• Clears the following alarm or warning status.

- Current alarm/warning status
- Alarm status history * (warning history is not preserved.)

• The ALM_CLR_MOD specifications are shown in the following table.
• A warning will occur and the command will be ignored in the following cases.

- During phases other than phases 2 and 3: Command warning1 (A.95A)
- If a Digital Operator is connected: Command warning1 (A.95A)
- If ALM_CLR_MOD is not within range: Data setting warning2 (A.94B)

4
5

ALM_CLR_

MOD

ALM_CLR_

MOD

6
7
8
9

10

11

12
13
14
15
16

WDT

RWDT

ALM_CLR_MODE

Description

Processing Time

0

Clear current alarm/warning status

Within 200 ms

1

Clear alarm status history

Within 2 s