5 Wiring

5.6.5 AC/DC Reactor for Harmonic Suppression

5-24

5.6.5 AC/DC Reactor for Harmonic Suppression

(1) Reactor Types

The SERVOPACK has reactor connection terminals for power supply harmonic suppression. The type of reactor
to be connected differs depending on the SERVOPACK capacity. Refer to the following table.

Note: Select a proper AC or DC reactor for the input current to the SERVOPACK.

Refer to 2.5.2 Molded-case Circuit Breaker and Fuse Capacity for input current to each
SERVOPACK. For the kind of reactor, refer to 4.4.9 AC/DC Reactors for Power Supplied
Designed for Minimum Harmonics.

(2) Connecting a Reactor

Connect a reactor as shown in the following diagram.

Note: 1. The DC reactor’s

1 and

2 terminals are short-circuited before shipment. Remove the lead

wire between these two terminals and connect the DC reactor.

2. AC/DC reactor is an option.

Applicable

SERVOPACK Model

SGDS-

AC/DC Reactor

Model

Reactor Specifications

Impedance

(mH)

Rated

Current

(A)

Single-phase,
100 V

A5F

X5053

20.0

2.0

01F

X5053

02F

X5054

5.0

3.0

04F

X5056

2.0

5.0

Single-phase,
200 V

A5A

X5052

45.0

1.0

01A

X5052

02A

X5053

20.0

2.0

04A

X5054

5.0

3.0

08A

X5056

2.0

5.0

Three-phase,
200 V

10A

X5061

2.0

4.8

15A

Consult Factory

Consult Factory

Consult
Factory

20A

Consult Factory

Consult Factory

Consult
Factory

30A

Consult Factory

Consult Factory

Consult
Factory

AC Reactor

DC Reactor

SERVOPACK

L1

L2

AC reactor

Power supply

Single-phase Input

1

2

DC reactor

Three-phase Input

SERVOPACK

Advertising