1) first-step linear acceleration parameter, 2) second-step linear acceleration parameter, 3) acceleration switching speed – Yaskawa SGDS Sigma III Servo Amplifier User Manual

Page 208: 4) first-step linear deceleration parameter, 19 (1) first-step linear acceleration parameter

Advertising
background image

7.4 Settings According to Host Controller

7-19

(1) First-step Linear Acceleration Parameter

Set the first-step linear acceleration when 2-step acceleration is used.

(2) Second-step Linear Acceleration Parameter

Set the second-step linear acceleration, when 2-step acceleration is used.
When first-step acceleration is used, set Pn80B as the parameter for first-step acceleration.

(3) Acceleration Switching Speed

Set the speed for switching between first-step and second-step acceleration when 2-step acceleration is used.
When first-step acceleration is used, set the acceleration switching speed (Pn80C) to 0.

(4) First-step Linear Deceleration Parameter

Set the first-step linear deceleration when 2-step deceleration is used.

Speed

Time

Pn80B

Pn80A

Pn80C

Pn80E

Pn80F

Pn80D

Pn80A

First-step Linear Acceleration Parameter

Setting Range

Setting Unit

Factory Setting

Setting Validation

1 to 65535

10,000

reference units/s

2

100

Valid when DEN = 1

Position

Pn80B

Second-step Linear Acceleration Parameter

Setting Range

Setting Unit

Factory Setting

Setting Validation

1 to 65535

10,000

reference units/s

2

100

Valid when DEN = 1

Position

Pn80C

Acceleration switching speed

Setting Range

Setting Unit

Factory Setting

Setting Validation

0 to 65535

10,000

reference units/s

0

Valid when DEN = 1

Position

Pn80D

First-step Linear Deceleration Parameter

Setting Range

Setting Unit

Factory Setting

Setting Validation

1 to 65535

10,000

reference units/s

2

100

Valid when DEN = 1

Position

Advertising