11.2 List of Parameters

11-37

11.2.3 Monitor Modes

The following list shows monitor modes available.

Parameter

No.

Content of Display

Unit

Un000

Motor speed

RPM

Un001

Speed reference (displayed only in speed control mode)

RPM

Un002

Internal torque reference ( in percentage to the rated torque)

%

Un003

Rotation angle 1 (32-bit decimal code)

pulse

Un004

Rotation angle 2 (Angle to the zero-point (electrical angle))

deg

Un005

Input signal monitor

Un006

Output signal monitor

Un007

Input reference pulse speed (displayed only in position control mode)

RPM

Un008

Error counter (position error amount) (displayed only in position control mode)

reference

unit

Un009

Accumulated load ratio (in percentage to the rated torque: effective torque in cycle of 10
seconds)

%

Un00A

Regenerative load ratio (in percentage to the processable regenerative power: regenerative
power consumption in cycle of 10 seconds)

%

Un00B

Power consumed by DB resistance
(in percentage to the processable power at DB activation: display in cycle of 10 seconds)

%

Un00C

Input reference pulse counter (32-bit decimal code)
(displayed only in position control mode)

pulse

Un00D

Feedback pulse counter (32-bit decimal code)

pulse