4 absolute encoder home position offset, 4 absolu, 4 absolute encoder home position offset -37 – Yaskawa SGDS Sigma III Servo Amplifier User Manual

Page 226

Advertising
background image

7.7 Absolute Encoders

7-37

7.7.4 Absolute Encoder Home Position Offset

When an absolute encoder is used, the offset between the encoder position and the feedback position (APOS) can
be set.

Settings are as shown in the following figure. To set encoder position (X) as the machine home position (0), set
Pn808 to -X.

Pn808
Pn809

Absolute Home Position Offset

Setting Range

Setting Unit

Factory Setting

Setting Validation

-1073741823 to 1073741823

1 reference unit

0

Immediately

Position

Machine zero point (APOS)

Zero point

Encoder position

Encoder position: Zero point

Encoder position: X

Pn808