background image

6.5 Command Data Field

6-49

6.5 Command Data Field

This section describes command data in main commands and subcommands.

6.5.1 Latch Signal Field Specifications: LT_SGN

The latch signal field specifications (LT_SGN) can be designated using the following commands:
LATCH, EX_POSING, ZRET, LTMOD_ON
The latch signal field is used to select latch signals for position data, with the second byte of the above main
commands, or the eighteenth byte reserved area of the subcommands.
Refer to the following table for details on bit allocation.

• Latch Signal Field

Latch Signal Selection

• EXT1, EXT2, and EXT3 must be allocated to the CN1 input signal using parameter Pn511. If they are not allocated, the

latch operation will be undefined.

• The latch operation will also be undefined if phase C is selected for a fully closed encoder that does not use phase C.

D7

D6

D5

D4

D3

D2

D1

D0

0

0

0

0

0

0

LT_SGN

D1

D0

Latch Signal

0

0

Phase C

0

1

EXT1

1

0

EXT2

1

1

EXT3

INFO