12 write non-volatile parameter (pprm_wr: 1ch), 12 w, 12 write non-volatile parameter (pprm_wr: 1ch) -18 – Yaskawa SGDS Sigma III Servo Amplifier User Manual

Page 149

Advertising
background image

6 MECHATROLINK II Communications

6.3.12 Write Non-volatile Parameter (PPRM_WR: 1CH)

6-18

6.3.12 Write Non-volatile Parameter (PPRM_WR: 1CH)

Byte

PPRM_WR

Description

Command

Response

1

1CH

1CH

Processing
classifications

Data communica-
tions command
group

Synchronization
classifications

Asynchronous

2

ALARM

Processing time

Within 200 ms

Subcommand

Cannot be used

3

STATUS

• Saves parameters in E

2

PROM. If parameters are online parameters, those

parameters will become effective immediately.
Offline parameters are enabled with the Set Up Device command (CONFIG)
transmission communication after setting.

• Can be used during phases 2 and 3.
• A warning will occur and the command will be ignored in the

following cases.
- During phase 1: Command warning 1 (A.95A)
- If communications are being transmitted to a Digital Operator:
Command warning 1 (A.95A)
- If NO is not within range: Data setting warning1 (A.94A)
- If SIZE does not match:Data setting warning 4 (A.94D)
- If PARAMETER is not within range: Data setting warning 2 (A.94B)

• If the calculation requires too much memory, Data setting warning 3 (A.94C).
• For details on NO, SIZE and PARAMETER, refer to the 11.2.2 List of

Parameters.

4
5

NO

NO

6
7

SIZE

SIZE

8

PARAMETER

PARAMETER

9

10

11

12
13
14
15
16

WDT