10 vibration suppression on stopping, 10 v, 10 vibration suppression on stopping -48 – Yaskawa SGDS Sigma III Servo Amplifier User Manual

Page 275

Advertising
background image

8 Adjustments

8.6.10 Vibration Suppression on Stopping

8-48

1. Sufficient precautions must be taken when setting the notch frequencies. Do not set the notch frequencies

(Pn409 or Pn40C) that is close to the speed loop’s response frequency. Set the frequencies at least four
times higher than the speed loop’s response frequency. Setting the notch frequency too close to the
response frequency may cause vibration and damage the machine. The speed loop response frequency is
the value of the Speed Loop Gain (Pn100) when the Moment of Inertia Ratio (Pn103) is set to the correct
value.

2. Change the Notch Filter Frequency (Pn409 or Pn40B) only when the motor is stopped. Vibration may

occur if the notch filter frequency is changed when the motor is rotating.

8.6.10 Vibration Suppression on Stopping

When the servo gain has been increased, there may be vibration upon stopping (e.g., limit cycle) even though
there is no vibration during operation. The function to suppress vibration on stopping, lowers the internal servo
gain only when stopping. After the time specified fo

r the Vibration Suppression Starting Time (Pn421

) has elapsed

from the time the difference of position reference becomes zero the internal servo gain is reduced at the rate
specified for the

Damping for Vibration Suppression on Stopping

(Pn420)

.

Set the Damping for Vibration Suppression on stopping (Pn420) is 50

% or higher, and the Vibration

Suppression Starting Time (Pn421) to 10 ms or longer. If lower value are set, the response characteristic
may become worse and vibration may occur.

Pn40D

2nd Step Notch Filter Q Value

Setting Range

Setting Unit

Factory Setting

Setting Validation

0.50 to 10.00

0.01

0.70

Immediately

Speed

Position

Torque

IMPORTANT

Difference of
Position reference

Servo gain

Difference of
Position reference = 0

K Pn420/100

K

K

Pn421

Pn420

Damping for Vibration Suppression on Stopping

Setting Range

Setting Unit

Factory Setting

Setting Validation

10% to 100%

1%

100%

Immediately

Pn421

Vibration Suppression Starting Time

Setting Range

Setting Unit

Factory Setting

Setting Validation

0 to 65,535 ms

1 ms

1,000 ms

Immediately

Position

Position

IMPORTANT

Advertising