6 MECHATROLINK II Communications
6.3.14 Apply Brake (BRK_ON: 21H)
6-20
6.3.14 Apply Brake (BRK_ON: 21H)
• Related Parameter
Byte
BRK_ON
Description
Command
Response
1
21H
21H
Processing
classifications
Control com-
mand group
Synchronization
classifications
Asynchronous
2
ALARM
Processing time
Within communi-
cations cycle
Subcommand
Cannot be used.
3
STATUS
• Applies brake. This command is enabled when the parameter Pn50F.2 is not
set to 0. This command is enabled only while the servo is OFF.
• Can be used during phases 2 and 3.
• A warning will occur and the command will be ignored in the following cases.
- During phase 1: MECHATROLINK II command warning1 (A.95A)
- If Pn50F.2 is set to 0: Command setting warning 3 (A.95C)
• Brake signal output timing
4
5
MONITOR 1
6
7
8
9
MONITOR 2
10
11
12
13
SEL_MON 1/2
SEL_MON 1/2
14
IO_MON
15
16
WDT
RWDT
Pn No.
Description
Pn50F.2
/BK signal allocation
Within 3 ms