6.3 Main Commands

6-15

6.3.9 MECHATROLINK II Connection (CONNECT: 0EH)

• Details of COM_MOD

* If SYNCMOD = 0, the SERVOPACK transmits the SYNC_SET command and changes the

communications to Phase 3.

Byte

CONNECT

Description

Command

Response

1

0EH

0EH

Processing
classifications

Network com-
mand group

Synchronization
classifications

Asynchronous

2

ALARM

Processing time

Communications
cycle or more

Subcommand

Cannot be used

3

STATUS

• Establishes a MECHATROLINK II connection. Sets the communications

mode according to COM_MOD.

• VER: Version
• Set VER to 21H (Ver. 2.1).
• COM_MOD: Communications mode. Refer to the following table.
• COM_TIM: Communications cycle

Set the multiple number of transmission cycle in the range of 0.5 to 32.
When the transmission cycle is 0.5 [ms]

≤ transmission cycle [ms] ×

COM_TIM

≤ 32 [ms] and the communications cycle is set in multiples of 0.5

ms.

• A warning will occur and the command will be ignored in the following cases.

- If COM_MOD is not within range: Data setting warning 2 (A.94B)
- If COM_TIM is not within range: Data setting warning 2 (A.94B)
- If the transmission bytes is 17, and SUBCMD is 1: Data setting
warning 2 (A.94B)
- If VER is not equal to 21H in the MECHATROLINK communications
mode: Data setting warning 2 (A.94B)

4
5

VER

VER

6

COM_MOD

COM_MOD

7

COM_TIM

COM_TIM

8
9

10

11

12
13
14
15
16

WDT

RWDT

D7

D6

D5

D4

D3

D2

D1

D0

SUBCMD

0

0

0

DTMOD

SYNCMOD

0

• SYNCMOD*:

0: Asynchronous communication
1: Synchronous communication
DTMOD: Data transfer method
00, 11: Single transfer
01: Consecutive transfer
SUBCMD:
0: Subcommand not used
1: Subcommand used

• Set the 0 in the other bit.

Phase 1

Phase 2

Phase 3

SYNCMOD=0

SYNC_SET

Warning/alarm

SYNCMOD=1