2 option field specifications: option, 2 option field specifications: option -50, 2 option field specifications – Yaskawa SGDS Sigma III Servo Amplifier User Manual

Page 181: Option, Option for

Advertising
background image

6 MECHATROLINK II Communications

6.5.2 Option Field Specifications: OPTION

6-50

6.5.2 Option Field Specifications: OPTION

The option field specifications (OPTION) can be designated using the following main commands:
SV_ON, HOLD, INTERPOLATE, POSING, FEED, LATCH, EX_POSING, ZRET, VELCTRL, TRQCTRL
The option field is used to add motion command functions, with the third to fourth byte reserved area of the
above main commands.
Refer to the following table for details on bit allocation.

• Option Field

D7

D6

D5

D4

D3

D2

D1

D0

0

0

0

ACCFIL

0

0

0

D15

D14

D13

D12

D11

D10

D9

D8

N-CL

P-CL

P-PI-CLR

V-PPI

0

0

G-SEL

Bit

Name

Description

Set

Value

Details

D0

0

D1

0

D2

0

D3

ACCFIL

Acceleration/deceleration filter
Note: Never change acceleration/deceleration filter
during output (when DEN of STATUS is set to 0).

0

No acceleration/deceleration
filter

1

Exponential acceleration/
deceleration

D4

2

S-curve
acceleration/deceleration

3

Do not set.

D5

0

D6

0

D7

0

D8

G-SEL

Gain switching

0

First gain

1

Second gain

D9

2

Third gain

3

Fourth gain

D10

0

D11

0

D12

PPI

Speed loop P/PI control

0

PI control

1

P control

D13

P_PI_CL
R

Position loop position Integral clear

0

Clear.

1

Does not clear.

D14

P-CL

Forward torque limit

0

Controls torque.

1

Does not control torque.

D15

N-CL

Reverse torque limit

0

Controls torque.

1

Does not control torque.