4 connection example of linear scale by renishaw, 1) serial converter unit model: jzdp-a005-000, 2) connection example – Yaskawa SGDS Sigma III Servo Amplifier User Manual

Page 285: 3) dimensional drawing, 4 conn

Advertising
background image

9 Fully-closed Control

9.2.4 Connection Example of Linear Scale by Renishaw

9-6

9.2.4 Connection Example of Linear Scale by Renishaw

(1) Serial Converter Unit Model: JZDP-A005-000
(2) Connection Example

(3) Dimensional Drawing

Note: Do not use empty pins.

The linear scale (analog 1Vp-p output, D-sub 15-pin) by Renishaw Inc. can be directly connected. However, the BID
and DIR signals are not connected.
Use the linear scale end connector to change the home position specifications of the linear scale.

SERVOPACK

Serial converter unit

SGDS-

12A

JZSP-CLP20-

Linear encoder

by Renishaw Inc.

JZDP-A005-000

CN4

CN1

CN2

D-sub 15-pin connector

82 (3.23)

65 (2.56) 72 (2.84)

90 (3.54)

1.5 (0.59)

3

(0.12)

14.35 (0.57)

23 (0.906)

300

±

30

(1

1.81

± 1.18)

4

× M5 tapped holes,

depth 10 (0.39)

2

× #4-40 UNC tapped holes

CN1

CN2

Nameplate

4

× φ 4.2

(0.17) holes

2

× φ 4.2

(0.17) holes

10 (0.39)

52 (2.05)

60 (2.36)

Dimensions in mm (in)

17-series connector

model:

17JE-13090-02 (D2C)

(socket) by DDK Ltd.

SERVOPACK end
Serial data output

Linear encoder end
Analog signal input

17-series connector

model:

17JE-13150-02 (D2C)

(socket) by DDK Ltd.

Pin No.

Signal

1

+5V
S-phase output
Empty
Vq
0V

/S-phase output

Empty
0V(Vq)
Empty
Shield

2
3
4
5
6
7
8
9

Case

Pin No.

Signal

1

/cos input (V1-)

2
3

Ref input (V0+)

/sin input (V2-)

4

+5V

5

5Vs

6

Empty (Vx)

7

Limit switch (Vq)

8

cos input (V1+)

9

sin input (V2+)

10

/Ref input (V0

−)

11

Empty

12

0V

13
14

Inner (0V)

15

0Vs

Empty

Shield

Case

1

8

9

6

1

5

9

15

CN1

CN2

SERVOPACK does not have
the function to process Vq
signals.

Advertising