2.5 Selecting Peripheral Devices

2-27

2.5.4 Regenerative Resistors

Note: 1. If the SERVOPACK cannot process the regenerative power, an external regenerative resistor is

required. Refer to 4.4.3 External Regenerative Resistor and 5.7 Connecting Regenerative
Resistors
.

2. The following table shows the manufacturers of each device.

Main Circuit

Power Supply

SERVOPACK Model

Regenerative Resistor

(Refer to 4.4.3 and 5.7)

Capacity

(kW)

SGDS-

Built-in

Externally Connected

Resistance

(

Ω)

Capacity

(W)

Single-phase
100 V

0.05

A5F

0.10

01F

0.20

02F

0.40

04F

Single-phase
200 V

0.05

A5A

0.10

01A

0.20

02A

0.40

04A

0.80

08A

50

60

Three-phase
200 V

1.0

10A

50

60

1.5

15A

30

70

2.0

20A

25

140

3.0

30A

12.5

140

Peripheral Device

Manufacturer

External Regenerative
Resistor

Iwaki Wireless Research Institute