3 setting the speed bias, 4 speed feedback filter time constant, 5 speed feedback compensation – Yaskawa SGDS Sigma III Servo Amplifier User Manual

Page 255

Advertising
background image

8 Adjustments

8.6.3 Setting the Speed Bias

8-28

8.6.3 Setting the Speed Bias

The settling time for positioning can be reduced by setting the following parameters to add bias in the speed
reference block in the SERVOPACK.

8.6.4

Speed Feedback Filter Time Constant

8.6.5 Speed Feedback Compensation

The speed feedback compensation can be used to reduce vibration and allow a higher speed loop gain to be set. In
the end, the speed feedback compensation allows the positioning settling time to be reduced because the position
loop gain can also be increased if the speed loop gain can be increased.

Pn107

Bias

Setting Range

Setting Unit

Factory Setting

Setting Validation

0 to 450 RPM

1 RPM

0 RPM

Immediately

Pn108

Bias Addition Width

Setting Range

Setting Unit

Factory Setting

Setting Validation

0 to 250 units

1 Reference units

7 units

Immediately

Position

Position

To reduce the positioning time, set these parameters
based on the machine’s characteristics.
The Bias Addition Width (Pn108) specifies when the
Bias (Pn107) is added and the width is expressed in
position error pulse units. The bias input will be
added when the position error pulse value exceeds
the width set in Pn108.

Bias addition width

Bias set

Bias (Pn107)

Bias (Pn107)

No bias

Pn108

Bias addition width

Pn108

Pn108

Position error pulse

Speed reference

Pn308

Speed Feedback Filter Time Constant

Setting Range

Setting Unit

Factory Setting

Setting Validation

0.00 to 655.35 ms

0.01ms

0.00ms

Immediately

Sets the 1st-order filter for the speed loop’s speed feedback. Makes the motor speed smoother and reduces vibration. If the
set value is too high, it will introduce a delay in the loop and cause poor responsiveness.

Speed

Position

Pn110

Online Autotuning Method

Setting Range

Setting Unit

Factory Setting

Setting Validation

0012

After restart

Speed

Position

Pn111

Speed Feedback Compensation

Setting Range

Setting Unit

Factory Setting

Setting Validation

1% to 500%

1%

100%

Immediately

Speed

Position

Parameter

Function

Pn110

n.

0

Speed feedback compensation is used.

n.

1

Speed feedback compensation is not used. (Standard speed feedback)

Advertising