Setting parameters for normal autotuning – Yaskawa SGDS Sigma III Servo Amplifier User Manual

Page 354

Advertising
background image

11.3 Using the Adjusting Command (ADJ: 3EH)

11-39

• Setting Parameters for Normal Autotuning

The following flowchart shows the procedure for setting the parameters for normal autotuning.

Start

Operate with factory
settings of parameters.

Set to always perform tuning.

(Set Pn110.0 to 1.)

Adjust the machine rigidity
setting.

(Set Pn110.0 to 2.)

Yes

Load

moment of inertia

changes?

Operation

OK?

Adjust the friction
compensation.

(Set Pn110. 0 to 2)

End

Make servo gain
adjustments manually*:

No

Yes

No

Yes

No

Yes

No

Yes

No

Save the results of autotuning to
parameters. From the next time,
execute autotuning using the
saved value as the initial value.

Operation

OK?

Operation

OK?

Operation

OK?

Clear the normal
autotuning.