8.7 Analog Monitor

8-51

(1) Related Parameters

The following signals can be monitored.

(a) Pn006 and Pn007: Function Selections

* When using speed control, the position error monitor signal is 0.

Parameter

Description

Monitor Signal

Measurement Gain

Remarks

Pn006
Pn007

n.

00

Motor speed

1 V/1000 RPM

Pn007 Factory
Setting

n.

01

Speed reference

1 V/1000 RPM

n.

02

Gravity Compensation Torque
(Pn422) subtract from Torque
reference

1 V/100

% Rated torque

Pn006 Factory
Setting

n.

03

Position error

0.05 V/reference unit

n.

04

Position amp error

0.05 V/reference unit

Position error after
electronic gear
conversion

n.

05

Position reference speed (speed
calculation)

1 V/1000 RPM

n.

06

Speed calculation

1 V/1000 RPM

n.

07

Reserved

n.

08

Positioning completed

Positioning completed: 5 V
Positioning not completed: 0 V

n.

09

Speed feed-forward

1 V/1000RPM

n.

0A

Torque feed-forward

1 V/100

% Rated torque

n.

0B

Reserved

n.

0C

n.

0D

Reserved

n.

0E

Reserved

n.

0F

Reserved

Advertising