Electronic gear ratio is given as, Set the parameters, Important – Yaskawa SGDS Sigma III Servo Amplifier User Manual

Page 205

Advertising
background image

7 Operation

7.4.2 Using the Electronic Gear Function

7-16

5. Electronic gear ratio is given as

.

If the decelerator ratio of the motor and the load shaft is given as
where m is the rotation of the motor and n is the rotation of the load shaft,

Make sure the electronic gear ratio satisfies the following condition:

The SERVOPACK will not work properly if the electronic gear ratio is outside this range. In this case,
modify the load configuration or reference unit.

6. Set the parameters.

Reduce the electronic gear ratio

to the lower terms so that both A and B are integers smaller than

1073741824, then set A and B in the respective parameters.

That is all that is required to set the electronic gear ratio.

Set the electronic gear ratio according to machine specifications.

Ball Screw

Circular Table

Belt and Pulley

5

0.001

= 5000 (reference u n it )

Load shaft

P: Pitch

P

1 revo lution =

P

reference u n it

Load shaft

1 revo lution =

360 ˚

reference u n it

D: Pulley

D

π D

Load shaft

1 r evo lution =

π D

referenc e uni t

B
A

----

 

 

n

m

----

Electronic gear ratio

B

A

=

No. of encoder pulses

× 4

Travel distance per load shaft revolution (reference unit)

× mn

IMPORTANT

0.01

≤ Electronic gear ratio B

A

100

B
A

----

 

 

B
A

Pn20E

Pn210

Electronic Gear
Ratio (Numerator)

Electronic Gear
Ratio (Denominator)

Pn20E

Electronic Gear Ratio (Numerator)

Setting Range

Setting Unit

Factory Setting

Setting Validation

1 to 1073741824 (2

30

)

None

4

After restart

Pn210

Electronic Gear Ratio (Denominator)

Setting Range

Setting Unit

Factory Setting

Setting Validation

1 to 1073741824 (2

30

)

None

1

After restart

Position

Position

M

Reference
input

SERVOPACK

servomotor

Electronic
gear

B
A

Advertising