3) servopack’s absorbable energy, 10 (3) servopack’s absorbable energy – Yaskawa SGDS Sigma III Servo Amplifier User Manual

Page 325

Advertising
background image

11 Appendix

11.1.3 Calculating the Required Capacity of Regenerative Resistors

11-10

(3) SERVOPACK’s Absorbable Energy

The following diagrams show the relationship between the SERVOPACK’s input power supply voltage and its
absorbable energy.

A5F to 02F

AC Input Power Supply Voltage (Vms)

SERVOPACK for 100 V

Absorbab

le Energy (J)

04F

0

15

20

30

39

29

14

20

47

50

35

10

5

25

40

100

110

120

90

Model:

SGDS-

01A to 04A

08A to 10A

AC Input Power Supply Voltage (Vms)

SERVOPACK for 200 V

Absorbab

le Energy (J)

05A

A5A

0

5

6

10

12

18

31

37

15

24

30

47

100

120

60

80

200

220

240

180

260

Model: SGDS-