3) servopack’s absorbable energy, 10 (3) servopack’s absorbable energy – Yaskawa SGDS Sigma III Servo Amplifier User Manual
Page 325
Advertising
11 Appendix
11.1.3 Calculating the Required Capacity of Regenerative Resistors
11-10
(3) SERVOPACK’s Absorbable Energy
The following diagrams show the relationship between the SERVOPACK’s input power supply voltage and its
absorbable energy.
A5F to 02F
AC Input Power Supply Voltage (Vms)
SERVOPACK for 100 V
Absorbab
le Energy (J)
04F
0
15
20
30
39
29
14
20
47
50
35
10
5
25
40
100
110
120
90
Model:
SGDS-
01A to 04A
08A to 10A
AC Input Power Supply Voltage (Vms)
SERVOPACK for 200 V
Absorbab
le Energy (J)
05A
A5A
0
5
6
10
12
18
31
37
15
24
30
47
100
120
60
80
200
220
240
180
260
Model: SGDS-