33 general-purpose servo control (svctrl: 3fh), 33 general-purpose, 33 general-purpose servo control (svctrl: 3fh) -41 – Yaskawa SGDS Sigma III Servo Amplifier User Manual

Page 172

Advertising
background image

6.3 Main Commands

6-41

6.3.33 General-purpose Servo Control (SVCTRL: 3FH)

• Sub-control: SUBCTRL

Select Latch Signal: LT_SGN

Byte

SVCTRL

Description

Command

Response

1

3FH

3FH

Processing
classifications

Compound com-
mand group

Synchronization
classifications

Synchronous,
asynchronous

2

SUBCTRL

ALARM

Processing time

Depends on pro-
cessing

Subcommand

Can be used

3

OPTION

STATUS

• This command is compatible with MECHATROLINK versions before Ver 1.0.

It is used to perform the general-purpose servo control.

• Latch Processing:

Supported. Select the latch signal using L_SGN in the SUBCTRL and set
SET_L to 1. When the selected latch signal is input, L_CMP in STATUS will
become 1. Perform latch processing again after the SET_L command is set to
0. The latch signal cannot be changed while SET_L is set to 1.

• Motion:

Any of the motions listed in the following table can be executed. Refer to
each motion item for operating specifications.

• Sequence Signals:

Any of the sequence signals listed in the following table can be executed.
Refer to each sequence item for operating specifications.

• During phase 1; Command warning 1 (A.95A). A command warning will

occur and the command will be ignored in the following cases.

4
5

TPOS

MONITOR1

6
7
8
9

TSPD

MONITOR2

10

OR

11

VFF

12
13

SEL_MON 1/2

SEL_MON 1/2

14

SQ_CMD

I/O_MON

15
16

WDT

RWDT

17

For
subcommands
use. Refer to
6.4
Subcommands
.

For
subcommands
use. Refer to
6.4
Subcommands
.

18
19
20
21
22
23
24
25
26
27
28
29

D7

D6

D5

D4

D3

D2

D1

D0

RESERVE

0

MOTION

Select motion

RESERVE

0

SET_L

Latch

command

L_SGN

Select latch signal

D1

D0

Latch Signal

0

0

Phase C

0

1

EXT1

1

0

EXT2

1

1

EXT3

Advertising