7.3 Settings According to Machine Characteristics

7-9

(2) Using the Overtravel Function

To use the overtravel function, connect the overtravel limit switch input signal terminals shown below to the
correct pins of the SERVOPACK CN1 connector.

Connect limit switches as shown below to prevent damage to the machines during linear motion.

Drive status with an input signal ON or OFF is shown in the following table.

(3) Enabling/Disabling Input Signals

Set the following parameters to specify whether input signals are used for overtravel or not. The factory setting is
“used.”

→ Input P-OT CN1-7

Forward Run Prohibited
(Forward Overtravel)

Position Control

→ Input N-OT CN1-8

Reverse Run Prohibited
(Reverse Overtravel)

Position Control

P-OT

CN1-7 at low level
when ON

Forward rotation allowed. Normal operation status.

CN1-7 at high level
when OFF

Forward run prohibited (reverse rotation allowed).

N-OT

CN1-8 at low level
when ON

Reverse rotation allowed. Normal operation status.

CN1-8 at high level
when OFF

Reverse run prohibited (forward rotation allowed).

Forward rotation end

Reverse rotation end

Limit
switch

Servomotor

SERVOPACK

CN1-7

CN1-8

N-OT

P-OT

Limit
switch

CN1-7

(P-OT)

CN1-8
(N-OT)

0 V

The short-circuit wiring shown in the figure can be
omitted when P-OT and N-OT are not used.

SERVOPACK

Parameter

Description

Pn50A

n.

1

Uses the P-OT input signal for prohibiting forward rotation. (Forward rotation is prohibited
when CN1-7 is open and is allowed when CN1-7 is at 0 V.) (Factory setting)

n.

8

Does not use the P-OT input signal for prohibiting forward rotation. (Forward rotation is
always allowed and has the same effect as shorting CN1-7 to 0 V.)

Pn50B

n.

2

Uses the N-OT input signal for prohibiting reverse rotation. (Reverse rotation is prohibited
when CN1-8 is open and is allowed when CN1-8 is at 0 V.) (Factory setting)

n.

8

Does not use the N-OT input signal for prohibiting reverse rotation. (Reverse rotation is
always allowed and has the same effect as shorting CN1-8 to 0 V.)