31 torque control (trqctrl: 3dh), 31 t, 31 torque control (trqctrl: 3dh) -39 – Yaskawa SGDS Sigma III Servo Amplifier User Manual

Page 170

Advertising
background image

6.3 Main Commands

6-39

6.3.31 Torque Control (TRQCTRL: 3DH)

• Related Parameters

• Speed Reference Option Operation

Byte

TRQCTRL

Description

Command

Response

1

3DH

3DH

Processing
classifications

Motion command
group

Synchronization
classifications

Asynchronous

2

ALARM

Processing time

Within communi-
cations cycle

Subcommand

Can be used

3

OPTION

STATUS

• The Servo does not perform position control and speed control, but directly

performs torque control.

• Can be used during phases 2 and 3.
• A command warning will occur and the command will be ignored in the

following cases.
- During phases other than phases 2 and 3: Command warning 1 (A.95A)

• OPTION field can be used. Refer to 6.5.2 Option Field Specifications:

OPTION for details.

• TOREF

TOREF is a torque reference and has signed 4 bytes of data. The unit for
torque reference is [maximum motor torque/40000000H]. The direction is
specified by the sign.
When the designation for TOREF is larger, it is clamped at the maximum
torque.

• During execution of this command, the following bits of STATUS are

allocated.
D11: V_LIM (speed limit bit)
0: Speed limit not detected
1: Speed limit detected

• MONITOR1, 2, 3, 4 (monitor)

The unit for torque is [maximum motor torque/40000000H].

• Setting the speed reference option (VLIM)

Setting range: 0 to 40000000H (maximum motor speed/40000000H)
Refer to on page 6-39.

4
5

VLIM

MONITOR1

6
7
8
9

TQREF

MONITOR2

10

11

12
13

SEL_MON 1/2

SEL_MON 1/2

14

IO_MON

15
16

WDT

RWDT

17

For
subcommands
use. Refer to
6.4
Subcommands
.

For
subcommands
use. Refer to
6.4
Subcommands
.

18
19
20
21
22
23
24
25
26
27
28
29

Pn No.

Description

Pn407

Speed Limit at Torque Control

Parameter

Description

Pn002

n.

0

VLIM is not available.
Set VLIM to 0.

n.

1

VLIM operates as the speed limit value.

Advertising