11 backlash compensation, 1) pn207=o1oo, 2) pn207=o2oo – Yaskawa SGDS Sigma III Servo Amplifier User Manual

Page 276: 12 position integral

Advertising
background image

8.6 Servo Gain Adjustment Functions

8-49

8.6.11 Backlash Compensation

(1) Pn207= 1

The Backlash Compensation Amount (Pn214) is added to forward reference.

(2) Pn207= 2

The Backlash Compensation Amount (Pn214) is added to reverse reference.

8.6.12 Position Integral

Pn214

Backlash Compensation Amount

Setting Range

Setting Unit

Factory Setting

Setting Validation

-32767 to 32767

reference units

Reference unit

0 reference units

Immediately

Pn215

Backlash Compensation Time Constant

Setting Range

Setting Unit

Factory Setting

Setting Validation

0.00 to 655.35 ms

0.01 ms

0.00 ms

Immediately

Position

Position

Parameter

Meaning

Pn207

n. 0

Disabled. (Factory Setting)

n. 1

Compensate in forward direction.

n. 2

Compensate in reverse direction.

Pn214

Pn214

Machine

Motor shaft

Forward direction

Machine

Motor axis

Pn214

Pn214

Machine

Motor shaft

Reverse direction

Machine

Motor axis

Pn11F

Position Integral

Setting Range

Setting Unit

Factory Setting

Setting Validation

0.0 to 5000.0 ms

0.1 ms

0.0 ms

Immediately

This function adds an integral control operation to the position loop. It is effective for electronic cam or electronic shaft
applications. Refer to the application examples in the user’s manual for the MP9

or MP2

Controllers from

Yaskawa for details.

Position

Advertising