32 adjusting (adj: 3eh), 32 adjusting, 32 adjusting (adj: 3eh) -40 – Yaskawa SGDS Sigma III Servo Amplifier User Manual
Page 171

6 MECHATROLINK II Communications
6.3.32 Adjusting (ADJ: 3EH)
6-40
6.3.32 Adjusting (ADJ: 3EH)
Byte
ADJ
Description
Command
Response
1
3EH
3EH
Processing
classifications
Compound com-
mand group
Synchronization
classifications
Asynchronous
2
00H
ALARM
Processing time
Depends on pro-
cessing
Subcommand
Cannot be used
3
STATUS
• This command is for maintenance. Data monitoring and adjustments can be
done.
• Use as SUBCODE = 01H. (When SUBCODE = 0, the operation is compatible
with SERVOPACKs in the
Σ II series.)
• Refer to 11.3 Using the Adjusting Command (ADJ: 3EH), for the way to use
set this command.
• A command warning will occur and the command will be ignored in the
following cases.
- During phase 1: Command warning 1 (A.95A)
- If a Digital Operator is connected: Command warning 1 (A.95A)
4
5
CCMD
CANS
6
CADDRESS
CADDRESS
7
8
CDATA
CDATA
9
10
11
12
13
14
15
16
WDT
RWDT