6 MECHATROLINK II Communications

6.3.1 No Operation (NOP: 00H)

6-6

6.3 Main Commands

The following sections describe main command specific items that are unique to the SGDS-

12A.

The MECHATROLINK II main commands are upwardly compatible with the MECHATROLINK commands.
They use the first to the twenty nineteenth bytes of the command and response data. 03H is set in command byte
0, and 01H is returned to response byte 0.

6.3.1 No Operation (NOP: 00H)

Byte

NOP

Description

Command

Response

1

00H

00H

Processing
classifications

Network com-
mand group

Synchronization
classifications

Asynchronous

2

ALARM

Processing time

Within transmis-
sion cycle

Subcommand

Can be used.

3

STATUS

• Returns the status of the ALM, WARNG, and CMDRDY in STATUS bytes

only. All other bits are not used. The response will be NOP when the power is
turned ON until initialization has been completed, and during this time, the
following status will be returned: CMDRDY: 0.

• Can be used during any phase.