28 external input positioning (ex_posing: 39h), 28 extern, 28 external input positioning (ex_posing: 39h) -34 – Yaskawa SGDS Sigma III Servo Amplifier User Manual

Page 165

Advertising
background image

6 MECHATROLINK II Communications

6.3.28 External Input Positioning (EX_POSING: 39H)

6-34

6.3.28 External Input Positioning (EX_POSING: 39H)

• Related Parameters

Byte

EX_POSING

Description

Command

Response

1

39H

39H

Processing
classifications

Motion command
group

Synchronization
classifications

Asynchronous

2

LT_SGN

ALARM

Processing time

Within communi-
cations cycle

Subcommand

Can be used

3

OPTION

STATUS

• Moves toward the target position (TPOS) at the target speed (TSPD). When a

latch signal is input midway, positioning is performed according to the final
travel distance for external position specified in the parameter from signal
input position. When no latch signal is input, positioning is performed for the
target position.

• Can be used during phases 2 and 3.
• A command warning will occur and the command will be ignored in the

following cases.
- During phase 1: Command warning 1 (A.95A)
- If the SERVOPACK is Servo OFF: Command warning 1 (A.95A)
- If the target speed (TSPD) exceeds the limit: Data setting warning 2 (A.94B)

• OPTION field can be used. Refer to 6.5.2 Option Field Specifications:

OPTION for details.

• The target position (TPOS) is a signed 4 bytes [reference unit]. It is set using

an absolute position in the reference coordinate system.

• The target speed (TSPD) is an unsigned 4 bytes. It is set using 0 to limit value

[reference unit/s].

• After the latch is input, any changes to the target position during motion will

be ignored.

• Use DEN (output complete) to confirm the completion of position reference

output.

• It takes 500

µs max. for the Request Latch Mode command to start.

4
5

TPOS

MONITOR1

6
7
8
9

TSPD

MONITOR2

10

11

12
13

SEL_MON 1/2

SEL_MON 1/2

14

I/O_MON

15
16

WDT

RWDT

17

For
subcommands.
Refer to 6.4
Subcommands
.

For
subcommands.
Refer to 6.4
Subcommands
.

18
19
20
21
22
23
24
25
26
27
28
29

Pn No.

Description

Pn No.

Description

Pn511

Input Signal Selections 5

Pn820

Latching Area Upper Limit

Pn80A

First-step Linear Acceleration Parameter

Pn822

Latching Area Lower Limit

Pn80B

Second-step Linear Acceleration Parameter

Pn80C

Acceleration Parameter Switching Speed

Pn80D

First-step Linear Deceleration Parameter

Pn80E

Second-step Linear Deceleration Parameter

Pn80F

Deceleration Parameter Switching Speed

Pn814

Final Travel Distance for External Positioning