3 SERVOPACK Specifications and Dimensional Drawings

3.3.5 Three-phase 200 V, 3.0~5.0kW

3-12

3.4 SERVOPACK Power Supply Capacities and Power Losses

The following table shows SERVOPACK power supply capacities and power losses at the rated output.

* 1. SERVOPACKs with a capacity of 50 to 400 W do not have built-in regenerative resistors. If the

regenerative energy exceeds the specified value, connect an external regenerative resistor. Refer to
11.1.3 Calculating the Required Capacity of Regenerative Resistors.

* 2. Regenerative resistor power losses are allowable losses. Take the following action if this value is

exceeded.

• Remove the lead from the internal regenerative resistor in the SERVOPACK.
• Install an external regenerative resistor.

Note: External regenerative resistors are optional. Refer to 5.7 Connecting Regenerative Resistors and

4.4.3 External Regenerative Resistor for details.

Table 3.1 SERVOPACK Power Losses at Rated Output

Main Circuit

Power

Supply

Maximum

Applicable

Servomotor

Capacity

kW

SERVOPACK

Model

SGDS-

Power Supply

Capacity

kW

Output

Current

(Effective

Value)

A

Main Cir-

cuit Power

Loss

W

Regenera-
tive Resis-

tor Power

Loss

W

Control

Circuit
Power

Loss

W

Total

Power

Loss

W

Single-
phase 100 V

0.05

A5F

0.25

0.66

5.2

∗1

13

18.2

0.10

01F

0.40

0.91

12

25

0.20

02F

0.60

2.1

16.4

29.4

0.40

04F

1.2

2.8

24

37

Single-
phase 200 V

0.05

A5A

0.25

0.66

4.6

17.6

0.10

01A

0.40

0.91

6.7

19.7

0.20

02A

0.75

2.1

13.3

26.3

0.40

04A

1.2

2.8

20

33

0.75

08A

2.2

5.5

47

12

*2

15

74

Three-phase
200 V

1.0

10A

2.3

7.6

55

12

*2

82

2.0

20A

4.3

11.6

92

14

*2

121

3.0

30A

5.9

18.5

120

28

*2

163