6.3.5 Set Up Device (CONFIG: 04H)

6-10

6.3.5 Set Up Device (CONFIG: 04H)

* +

α is setting of the Brake reference-Servo off delay time set in Pn506 (500 ms max.)

• Status and Output Signal during CONFIG Command Execution

Byte

CONFIG

Description

Command

Response

1

04H

04H

Processing
classifications

Control com-
mand group

Synchronization
classifications

Asynchronous

2

ALARM

Processing time

Within 4 s +

α

Subcommand

Cannot be used

3

STATUS

• Recalculates all currently set parameters and initializes positions, signals, etc.
• Can be used during phases 2 and 3.
• The SERVOPACK will change to Servo OFF if this command is received

when the SERVOPACK is Servo ON.

• A warning will occur and the command will be ignored in the following cases.

- During phase 1: Command warning1 (A.95A)
- If a Digital Operator is connected: Command warning1 (A.95A)

4
5
6
7
8
9

10

11

12
13
14
15
16

WDT

RWDT

Status and

Output Signal

Before CONFIG

During CONFIG

After CONFIG

ALM (status)

Current status

Current status

Current status

CMDRDY (status)

1

0

1

Other status

Current status

Not specified

Current status

ALARM (code)

Alarms currently
occurred

Alarms currently
occurred

Alarms currently
occurred

ALM
(CN1 output signal)

Current status

Current status

Current status

/S-RDY
(CN1 output signal)

Current status

OFF

Current status

Other output signals

Current status

Not specified

Current status