2) three-phase, 200 v – Yaskawa SGDS Sigma III Servo Amplifier User Manual

Page 96

Advertising
background image

4.4 Peripheral Devices

4-15

(2) Three-phase, 200 V

Select one of the following noise filters according to SERVOPACK capacity. For more details on selecting
current capacity for a noise filter, refer to 2.5.3 Noise Filters, Magnetic Contactors, Surge Protectors and AC/DC
Reactors
.
For connecting the noise filter, refer to 5.1.3 Typical Main Circuit Wiring Examples.

Dimensions in mm (in)

Model

Tolerance

FN258L-7/07

FN258L-16/07

A

±1 (±0.039)

255 (10.04)

305 (12.01)

B

-

126

±0.8 (4.96±0.031)

142

±0.8 (5.59±0.031)

C

±0.6 (±0.024)

50 (1.97)

55 (2.17)

D

-

225

±0.8 (8.86±0.031)

275

±0.8 (10.83±0.031)

E

±0.5 (±0.020)

240 (9.45)

290 (11.42)

F

±0.3 (±0.012)

25 (0.98)

30 (1.18)

G

±0.2 (±0.0079)

6.5 (0.26)

H

±10 (±0.39)

300 (11.81)

J

-

1

±0.1 (0.039±0.0039)

L

±1 (±0.039)

9 (0.35)

O

-

M5

P

-

AWG16

AWG14

Specifications

480 VAC, 7 A

480 VAC, 16 A

Applicable

Three-phase

200 V

05A

10A

Side view

Front/Side view

7A to 55A

G

P

B

O

E

A

D

H

L

C

F

J

Advertising