2 servopack model designations, 2 ser, 2 servopack model designations -5 – Yaskawa SGDS Sigma III Servo Amplifier User Manual
Page 34: 02 sgds - a 01 a r
Advertising

2.2 SERVOPACK Model Designations
2-5
2.2 SERVOPACK Model Designations
Select the SERVOPACK according to the applied servomotor.
Rated Output of
Applicable Servomotor
Code
A5
01
02
04
05
08
10
Rated Output
50 W
100 W
200 W
400 W
500 W
750 W
1.0 kW
Interface Specifications
Code
Specifications
MECHATROLINK-II IF+
Serial fully-closed Interface
Supply Voltage
Code
A
F
Voltage
02
SGDS -
A 01 A R
200 V
100 V
(100 V input, 200 V output:
Doubled voltage)
12
Design Revision Order
A,B
Start from A
Σ-III Series SGDS
SERVOPACK
Mounting Method
Code Mounting Method
Rack-mounted
R
Base-mounted
as standard
−
Rated Output of
Applicable Servomotor
Code
Rated Output
A5
50W
01
100W
02
200W
04
400W
05
500W
08
750W
10
1.0kW
15
1.5kW
20
2.0kW
30
3.0kW
12
Note: All SGDS amplifiers require 200V motors.
Advertising