2 servopack model designations, 2 ser, 2 servopack model designations -5 – Yaskawa SGDS Sigma III Servo Amplifier User Manual

Page 34: 02 sgds - a 01 a r

Advertising
background image

2.2 SERVOPACK Model Designations

2-5

2.2 SERVOPACK Model Designations

Select the SERVOPACK according to the applied servomotor.

Rated Output of

Applicable Servomotor

Code

A5

01

02

04

05

08

10

Rated Output

50 W

100 W

200 W

400 W

500 W

750 W

1.0 kW

Interface Specifications

Code

Specifications

MECHATROLINK-II IF+
Serial fully-closed Interface

Supply Voltage

Code

A

F

Voltage

02

SGDS -

A 01 A R

200 V

100 V

(100 V input, 200 V output:

Doubled voltage)

12

Design Revision Order
A,B

Start from A

Σ-III Series SGDS

SERVOPACK

Mounting Method

Code Mounting Method

Rack-mounted

R

Base-mounted

as standard

Rated Output of

Applicable Servomotor

Code

Rated Output

A5

50W

01

100W

02

200W

04

400W

05

500W

08

750W

10

1.0kW

15

1.5kW

20

2.0kW

30

3.0kW

12

Note: All SGDS amplifiers require 200V motors.

Advertising