6 MECHATROLINK II Communications

6.3.20 Release Latch Mode (LTMOD_OFF: 29H)

6-26

6.3.20 Release Latch Mode (LTMOD_OFF: 29H)

Byte

LTMOD_OFF

Description

Command

Response

1

29H

29H

Processing
classifications

Control com-
mand group

Synchronization
classifications

Asynchronous

2

ALARM

Processing time

Within communi-
cations cycle

Subcommand

Can be used

3

STATUS

• Releases the modal latch mode.
• Can be used during phases 2 and 3.
• During phase 1 Command warning 1(A.95A) will occur and the command

will be ignored.

• Check that CMDRDY is 1 to confirm that the Release Latch Mode command

has been received.
- It takes 500

µs max. for the Release Latch Mode command to start.

• Interference with another latch mode command

- During the execution of a command such as LATCH, ZRET, EX_POSING,
or SVCTRL, the LTMOD_ON command cannot be used. If this command is
used during the execution of these commands, the warning Command
warning 4 (A.95D) will occur.