Yaskawa SGDS Sigma III Servo Amplifier User Manual

Page 339

Advertising
background image

11 Appendix

11.2.2 List of Parameters

11-24

Pn408

Torque Related Function Switch

2

0000

∆/

8.6.9

Pn409

1st Step Notch Filter Frequency

2

50 to 2000 Hz

1 Hz

2000 Hz

8.6.9

Pn40A

1st Step Notch Filter Q Value

2

0.50 to 10.00

0.01

0.70

Pn40C

2nd Step Notch Filter Frequency

2

50 to 2000 Hz

1 Hz

2000 Hz

Pn40D

2nd Step Notch Filter Q Value

2

0.50 to 10.00

0.01

0.70

Pn40F

2nd Step 2nd Torque Reference
Filter Frequency

2

100 to 2000 Hz

1 Hz

2000 Hz

Pn410

2nd Step 2nd Torque Reference
Filter Q Value

2

0.50 to 10.00

0.01

0.70

Pn411

3rd Step Torque Reference Filter
Time Constant

2

0 to 65535

µs

1 µs

0

µs

Pn412

1st Step 2nd Torque Reference
Filter Time Constant

2

0.00 to 655.35 ms

0.01 ms

1.00 ms

8.6.6

Pn413

1st Step 3rd Torque Reference
Filter Time Constant

2

0.00 to 655.35 ms

0.01 ms

1.00 ms

Pn414

1st Step 4th Torque Reference
Filter Time Constant

2

0.00 to 655.35 ms

0.01 ms

1.00 ms

Pn420

Damping for Vibration
Suppression on Stopping

2

10 to 100%

1%

100%

8.6.10

Pn421

Vibration Suppression Starting
Time

2

0 to 65535 ms

1 ms

1000 ms

Pn422

Gravity Compensation Torque

2

-200.00 to 200.00%

0.01 %

0.00%

Pn456

Sweep Torque Reference
Amplitude

2

1 to 800%

1%

15%

Pn501

Zero Clamp Level

2

0 to 10000 RPM

1 RPM

10 RPM

Pn502

Zero Speed Level

2

1 to 10000 RPM

1 RPM

20 RPM

Note:

: Can be changed at any time, and immediately validated after changing. (Called an online

parameter.)

∆: Validated after a Set Up Device command is sent, when loading and using parameters at

power ON. Also validated when turning OFF and then ON the power supply again after a
Write Non-volatile Parameter (PPRM_WR) command is sent.

Parameter

No.

Name

Data

Size

Setting Range

Unit

Factory

Setting

Changing

Method

Reference

Section

0

1

0

1

N/A

Uses 1st step notch filter for torque reference.

Uses the smaller value between motor max. speed or parameter Pn407 as
speed limit value.

Uses the smaller value between overspeed detection speed or parameter
Pn407 as speed limit value.

1st Step Notch Filter Selection
(Refer to "8.6.9 Torque Reference Filter.")

0

1

2nd step notch filter N/A

Uses 2nd step notch filter for torque reference.

2nd Step Notch Filter Selection
(Refer to "8.6.9 Torque Reference Filter.")

4th

digit

3rd

digit

2nd

digit

1st

digit

n.

Speed Limit Selection

Reserved (Do not change)

Changing Method

Changing Method

Changing Method

Advertising