8) automatic gain related parameters, 33 (8) automatic gain related parameters – Yaskawa SGDS Sigma III Servo Amplifier User Manual

Page 260

Advertising
background image

8.6 Servo Gain Adjustment Functions

8-33

(8) Automatic Gain Related Parameters

Pn12B

3rd Speed Loop Gain

Setting Range

Setting Unit

Factory Setting

Setting Validation

1.0 to 2,000.0 Hz

0.1 Hz

40.0 Hz

Immediately

Pn12C

3rd Speed Loop Integral Time Constant

Setting Range

Setting Unit

Factory Setting

Setting Validation

0.15 to 512.00 ms

0.01 ms

20.00 ms

Immediately

Pn12D

3rd Position Loop Gain

Setting Range

Setting Unit

Factory Setting

Setting Validation

1.0 to 2,000.0/s

0.1/s

40.0/s

Immediately

Pn413

1st Step 3rd Torque Reference Filter Time Constant

Setting Range

Setting Unit

Factory Setting

Setting Validation

0.00 to 655.35 ms

0.01 ms

1.00 ms

Immediately

Pn12E

4th Speed Loop Gain

Setting Range

Setting Unit

Factory Setting

Setting Validation

1.0 to 2,000.0 Hz

0.1 Hz

40.0 Hz

Immediately

Pn12F

4th Speed Loop Integral Time Constant

Setting Range

Setting Unit

Factory Setting

Setting Validation

0.15 to 512.00 ms

0.01 ms

20.00 ms

Immediately

Pn130

4th Position Loop Gain

Setting Range

Setting Unit

Factory Setting

Setting Validation

1.0 to 2,000.0/s

0.1/s

40.0/s

Immediately

Pn414

1st Step 4th Torque Reference Filter Time Constant

Setting Range

Setting Unit

Factory Setting

Setting Validation

0.00 to 655.35 ms

0.01 ms

1.00 ms

Immediately

Speed

Position

Speed

Position

Speed

Position

Speed

Position

Torque

Speed

Position

Speed

Position

Speed

Position

Speed

Position

Torque

Pn131

Gain Switching Time 1

Setting Range

Setting Unit

Factory Setting

Setting Validation

0 to 65,535 ms

1 ms

0 ms

Immediately

Pn132

Gain Switching Time 2

Setting Range

Setting Unit

Factory Setting

Setting Validation

0 to 65,535 ms

1 ms

0 ms

Immediately

Pn135

Gain Switching Delay 1

Setting Range

Setting Unit

Factory Setting

Setting Validation

0 to 65,535 ms

1 ms

0 ms

Immediately

Pn136

Gain Switching Delay 2

Setting Range

Setting Unit

Factory Setting

Setting Validation

0 to 65,535 ms

1 ms

0 ms

Immediately

Speed

Position

Speed

Position

Speed

Position

Speed

Position

Advertising