1 servopack main circuit wire size, 1) cable types, 2) single-phase for 100 v – Yaskawa SGDS Sigma III Servo Amplifier User Manual

Page 83: 3) single-phase for 200 v, 1 ser, 1 servopack main circuit wire size -2

Advertising
background image

4 Specifications and Dimensional Drawings of Cables and Peripheral Devices

4-2

4.1 SERVOPACK Main Circuit Wire Size

(1) Cable Types

The table shows the wire size and allowable currency for three cables. Use a cable whose specifications meet or
are less than the values in the table.

• 600 V Heat-resistant Vinyl Cable (HIV)

Note: The values in the table are only for reference.

(2) Single-phase for 100 V

(3) Single-phase for 200 V

Cable Types

Allowable

Conductor

Temperature

°C

Symbol

Name

PVC

Normal vinyl cable

-

IV

600-V vinyl cable

60

HIV

Temperature-resistant vinyl cable

75

AWG size

Nominal

Cross Section

Diameter

(mm

2

)

Configuration

(number of

wires/mm

2

)

Conductive

Resistance

(

Ω/km)

Allowable Currency

at Ambient Temperatures

(A)

30

°C

(86

° F)

40

°C

(104

°F)

50

°C

(122

° F)

20

0.5

19/0.18

39.5

6.6

5.6

4.5

-

0.75

30/0.18

26.0

8.8

7.0

5.5

18

0.9

37/0.18

24.4

9.0

7.7

6.0

16

1.25

50/0.18

15.6

12.0

11.0

8.5

14

2.0

7/0.6

9.53

23

20

16

12

3.5

7/0.8

5.41

33

29

24

10

5.5

7/1.0

3.47

43

38

31

8

8.0

7/1.2

2.41

55

49

40

6

14.0

7/1.6

1.35

79

70

57

External Terminal Name

Terminal

Symbol

SERVOPACK Model

SGDS-

A5F

01F

02F

Main circuit power input terminals

L1, L2

HIV1.25

HIV2.0

Servomotor connection terminals

U, V,W

HIV1.25

Control power input terminals

L1C, L2C

HIV1.25

External regenerative resistor connection terminals

B1/

, B2

HIV1.25

Ground terminal

HIV2.0 min.

External Terminal Name

Terminal

Symbol

SERVOPACK Model

SGDS-

A5A

01A

02A

04A

08A

Main circuit power input terminals

L1, L2

HIV1.25

HIV2.0

Servomotor connection terminals

U, V, W

HIV1.25

Control power input terminals

L1C, L2C

HIV1.25

External regenerative resistor connection terminal

B1/

, B2

HIV1.25

Ground terminal

HIV2.0 min.

Advertising