6 MECHATROLINK II Communications

6.5.6 Substatus Field Specifications: SUBSTATUS

6-54

6.5.6 Substatus Field Specifications: SUBSTATUS

The substatus field is used to monitor the subcommand status with the eighteenth byte reserved area of the
subcommands.

• Substatus Field

D8

EXT3

Third external latch signal input

0

OFF

1

ON

D9

BRK

Brake output

0

Released

1

Locked

D10

Reserved

0

D11

Reserved

0

D12

IO12

CN1 input signal selected in Pn81E.0

0

OFF

1

ON

D13

IO13

CN1 input signal selected in Pn81E.1

0

OFF

1

ON

D14

IO14

CN1 input signal selected in Pn81E.2

0

OFF

1

ON

D15

IO15

CN1 input signal selected in Pn81E.3

0

OFF

1

ON

Bit

Name

Description

Set

Value

Settings

D7

D6

D5

D4

D3

D2

D1

D0

SBCMDRDY SBWARNG

SBALM

Bit

Name

Description

Set

Value

Details

D0

SBALM

Subcommand alarm occurrence

0

None

1

Alarm occurs.

D1

SBWARNG

Subcommand warning occurrence

0

None

1

Warning occurs.

D2

SBCMDRDY Subcommand ready

(Subcommand reception enabled)

0

Subcommands cannot be
received.
(busy)

1

Subcommand can be
received.
(ready)