4.1 SERVOPACK Main Circuit Wire Size

4-3

(4) Three-phase for 200 V

Note: 1. Wire sizes were selected for three cables per bundle at 40

°C ambient temperature with the rated

current.

2. Use cable with withstand voltage of 600 V for main circuits.
3. If cables are bundled in PVC or metal ducts, consider the reduction ratio of the allowable current.
4. Use heat-resistant cable under high ambient or panel temperatures where normal vinyl cable will

rapidly deteriorate.

5. Use cable within the allowable moment of inertia.
6. Do not use in continuous regenerating status.

External Terminal Name

Terminal

Symbol

SERVOPACK Model

SGDS-

10AE

1.5AE

2.0AE

3.0AE

Main circuit power input terminals

L1, L2, L3

HIV2.0

Servomotor connection terminals

U, V, W

HIV2.0

Control power input terminals

L1C, L2C

HIV1.25

External regenerative resistor connection terminals

B1/

, B2

HIV2.0

Ground terminal

HIV2.0 min.